Romexis software release 6.4.4

3D imaging module

Improvements to the cleaning tool of 3D rendering

You may now select between a round-shaped and a square-shaped brush tool. When the Limit Depth check box is selected, the material will be removed to the depth specified.

Screenshot 2023-09-29 at 12.53.52.png

Screenshot 2023-09-29 at 12.09.46.png

Hiding CBCT data from the 3D-rendered view

The new skull button enables hiding CBCT data easily from the 3D-rendered view. The overlayed objects such as intraoral scans and segmented objects will stay visible.

Screenshot 2023-09-29 at 12.11.35.png

Adjusting the overlay transparency

It is now possible to adjust the transparency of overlayed objects in the 3D-rendered view.

Screenshot 2023-09-29 at 12.13.26.png

Stronger colouring of PLY scans in the 3D-rendered view

In the new software version, fitted PLY scans are visualised with brighter colours than before.

Screenshot 2023-09-29 at 12.15.10.png

UNDO and REDO for implants

It is now possible to undo and redo implant and crown movements or generic crown resizing. You can use the arrows in the toolbar or the following keyboard shortcuts: Ctrl + Z for undo and Ctrl + Y or Ctrl + Shift + Z for redo.

Screenshot 2023-09-29 at 12.16.55.png

Moving cross-sectional and axial slices

You can move axial and cross-sectional slice positions by dragging the reference lines on top of the Panoramic view.

Screenshot 2023-09-29 at 12.18.53.png

Other changes and major fixes

• Opening the Implant library dialog is now instant and requires no waiting time
• The Abc text annotation button will be automatically deactivated after use
• Fix for the implant randomly appearing in the wrong place in the Panoramic view
• Fix for the view port randomly turning black
• Fix for the SuperPan randomly failing with large volumes
• Fix in the Romexis® Viewer for measurements occasionally placed outside the viewing area

Screenshot 2023-09-29 at 12.20.59.png

3D cephalometry module

New analysis type

The 3D cephalometry module has been updated with a new 3D cephalometric analysis type, Transversal Analysis. The benefits of the 3D cephalometric transverse analysis include a more comprehensive and precise assessment of transverse relationships, aiding in the accurate diagnosis and treatment planning of complex orthodontic cases.

Screenshot 2023-09-29 at 12.25.10.png

CMF surgery module

New jaw segmentation wizard

The jaw segmentation wizard has been completely redesigned into an easy-to-use and intuitive workflow.

Screenshot 2023-09-29 at 12.27.53.png

Improved visualisation of skull 3D models

The skull model visualisation has been improved, making the handling of skull models smoother and faster than before.

Snapshot

It is now possible to create 2D snapshots of the 3D rendering and slice views that are stored in the Romexis 3D module. They can be used e.g. in documenting the case using MS PowerPoint or MS Word.

Screenshot 2023-09-29 at 12.30.02.png

New tools

New tool for trimming the dental area
The Trim dental area tool is an easy-to-use tool for trimming the dental part of the skull, obtaining a clear and precise visualisation of the occlusion by removing

Screenshot 2023-09-29 at 12.33.03.png

Screenshot 2023-09-29 at 12.33.43.png

Measure length
It is now possible to measure the length between two points during the planning session. The measurement can be stored in a 2D snapshot for later use, if needed.

Screenshot 2023-09-29 at 12.35.33.png

Measure angle
It is now possible to measure the angle between three points during the planning session. The measurement can be stored in a 2D snapshot for later use, if needed.

Screenshot 2023-09-29 at 12.36.50.png

Reset measurements
The Reset measurement button deletes all distance and angle measurements from the case.

Screenshot 2023-09-29 at 12.38.31.png

STL export for surgery plans

The simulated surgery plan can now be exported as an STL file, allowing e.g. the 3D printing of the planned post-operative situation or importing it into a CAD software for further planning and designing.

Screenshot 2023-09-29 at 12.40.00.png

Screenshot 2023-09-29 at 12.40.39.png

Export analysis to a text file

The selected analysis with the anatomical landmarks can be exported as a .txt file for using the information in presentations or storing it in other systems.

Screenshot 2023-09-29 at 12.42.13.png

Other changes

• CMF case can be imported as a compressed .zip file from the 3D import
• CMF case will be exported as a .zip file
• Measurement and landmark updates to the Orthognathic analysis
• Possibility to add nerves at any phase of the workflow
• Checkboxes used in the Segment tree to select bone segments instead of a row selection

CAD/CAM module

Improvements and new features on Scan tab

• Improved scanning workflow
   - Enhanced soft tissue removal
   - Speed upgrade
   - Improved alignment accuracy
• New lock area feature
• New thermal-compensated colour calibration feature
• New option to set up a pop-up dialogue to appear automatically before scanning, on which the user selects the indication type for the case
   - The selected indication type is used as the case name on the Send tab and in Patient Management
• New user settings:
   - Setting to define preferred appearances for the colour model and the stone model
   - Setting to select a pre-set workflow as the default workflow

Screenshot 2023-09-29 at 12.47.05.png

New features on the Analyse tab

• New zoom slider

New features on the Send tab

• Scans can now be sent directly to DICOM PACS using the new DICOM Storage button
• Changes to the Case list:
   - The CAD/CAM case will be named automatically according to the indication, if it has been selected on the Scan tab
   - Empty CAD/CAM cases without scans are removed from the case list when the patient is closed

Screenshot 2023-09-29 at 12.49.20.png

Screenshot 2023-09-29 at 12.49.58.png

2D cephalometric analysis module

The 2D cephalometric analysis module has been enhanced with the following improvements:
• The automatic tracing of PA X-rays now possible
• The automatic tracing model for lateral X-rays updated
• A new hard tissue silhouette for the sphenoid bone now available
• Performance when using high resolution photos in the analysis improved
• Exports (Snapshot, Copy to Clipboard, Custom reports) improved, which produces more predictable results based on what is seen on the screen
• Excel reports now display X-ray image dates instead of analysis dates

Screenshot 2023-09-29 at 12.52.14.png